ACCU-CODER - 300354-006 - 15T-02SF-0500N5RHV-F01-T2 S740

Price:

550.00


+52 8113397295 +52 8110928974 +52 8113397293 +52 8110928974
ADAM ADVANTECH - ADAM-4060
ADAM ADVANTECH - ADAM-4060
150.00
150.00
EGE - P31132 - IGMF 02 GSP
EGE - P31132 - IGMF 02 GSP
280.00
280.00
Nuevo

ACCU-CODER - 300354-006 - 15T-02SF-0500N5RHV-F01-T2 S740

Nuevo

http://grupomi.com/web/image/product.template/359087/image_1920?unique=901eeb1

550.00 550.0 USD 550.00 IVA excluido

550.00 IVA excluido

Not Available For Sale


    Esta combinación no existe.

    Requerimiento de cotización Creado

    Compartir :
    1 año de garantía
    Tiempo de entrega: 1-3 días
    Envíos por DHL Express

    Electrical
    Input Voltage .................................5 VDC ±10% Fixed Voltage
    4.75 to 28 VDC max for temperatures up
    to 85° C
    4.75 to 24 VDC for temperatures between
    85° and 100° C
    Input Current .................................140 mA max (65 mA typical for most
    configurations) with no output load
    Output Format ..............................Incremental – Two square waves in
    quadrature with channel A leading B for
    clockwise shaft rotation, as viewed from
    the encoder mounting face. See Waveform
    Diagrams.
    Output Types .................................Open Collector – 20 mA max per channel
    Push-Pull – 20 mA max per channel
    Pull-Up – Open Collector with 2.2K ohm
    internal resistor, 20 mA max per channel
    Line Driver – 20 mA max per channel
    (Meets RS 422 at 5 VDC supply)
    Index ................................................Once per revolution
    1 to 400 CPR: Ungated
    401 to 10,000 CPR: Gated to output A
    See Waveform Diagrams.
    Max. Frequency .............................Standard Frequency Response is
    200 kHz for CPR 1 to 2540
    500 kHz for CPR 2541 to 5000
    1 MHz for CPR 5001 to 10,000
    Extended Frequency Response (optional) is
    300 kHz for CPR 2000, 2048, 2500, and 2540
    Electrical Protection .....................Reverse voltage and output short circuit
    protected. NOTE: Sustained reverse voltage
    may result in permanent damage.
    Noise Immunity ............................Tested to BS EN61000-6-2;
    BS EN50081-2; BS EN61000-4-2;
    BS EN61000-4-3; BS EN61000-4-6;
    BS EN500811
    Quadrature .....................................67.5° electrical or better is typical,
    Edge Separation............................54° electrical minimum at
    temperatures > 99° C
    Waveform Symmetry ...................180° (±18°) electrical (single channel
    encoder)
    Accuracy..........................................Within 0.017° mechanical or 1 arc-minute
    from true position (for CPR > 189)
    Commutation ................................Up to 12 pole. Contact Customer Service for
    availability.
    Comm. Accuracy ...........................1° mechanical
    Mechanical
    Max Shaft Speed ...........................8000 RPM. Higher speeds may be
    achievable, contact Customer Service.
    Bore Tolerance ...............................-0.0000" / +0.0006"
    User Shaft Tolerances
    Radial Runout ............................0.008" max
    Axial Endplay .............................±0.030" max
    Starting Torque .............................IP50 Hollow Bore: 0.2 oz-in
    IP50 Thru-Bore: 0.3 oz-in
    IP64: 0.6 oz-in
    Moment of Inertia ........................6.7 x 10-5 oz-in-sec2 (4.8 gm-cm2)
    Weight .............................................3 oz typical
    Environmental
    Storage Temp .................................-25° to 85° C
    Humidity .........................................98% RH non-condensing
    Vibration .........................................10 g @ 58 to 500 Hz
    Shock ...............................................80 g @ 11 ms duration
    Sealing .............................................IP50 standard; IP64 available
    Specifications